Specifications

Model SE 2KTL SE 3KTL SE 4KTL SE 5KTL
EfficiencyAvailable
Max. Efficiency 97.80% 97.80% 98.00% 98.00%
European Efficiency 97.00% 97.00% 97.40% 97.40%
Input(DC)
Max. Input Power 2,200W 3,300W 4,400W 5,500W
Max. Input Voltage 600V 600V 600V 600V
Max. Input Current 12.5A 12.5A 20.8A(2*10.4A) 20.8A(2*10.4A)
Min. Operating Voltage 90V 90V 90V 90V
MPPT Operating Voltage Ranger 70V-580V 70V-580V 70V-580V 70-580V
MPPT Operating Voltage Ranger(Full-Load) 200V-520V 240V-520V 200V-520V 240V-520V
Max. Number of PV Strings 1 1 2 2
No. of MPPTs 1 1 2 2
Output(AC)
Rated AC Active Power 2,000W 3,000W 4,000W 5,000W
Max. AC Apparent Power 2,100VA 3,150VA 4,200VA 5,250VA
Max. AC Active Power (PF=1) 2,100W 3,150W 4,200W 5,250W
Max. AC Output Current 9.5A 14.3A 19.0A 23.6A
Rated AC Voltage 220V/230V,L N PE 220V/230V,L N PE 220V/230V,L N PE 220V/230V,L N PE
AC Voltage Range* 180V-242V 180V-242V 180V-242V 180V-242V
Rated Grid Frequency 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz
Grid Frequency Range** 45Hz-55Hz/55Hz-65Hz 45Hz-55Hz/55Hz-65Hz 45Hz-55Hz/55Hz-65Hz 45Hz-55Hz/55Hz-65Hz
THDI <3% <3% <3% <3%
DC Current Injection <0.5%ln <0.5%ln <0.5%ln <0.5%ln
Adjustable Power Factor >0.99 Rated power (adjustable range 0.8 lead - 0.8 hysteresis)
Protection
Input DC switch optional
Anti-islanding protection support
AC overcurrent protection support
AC short circuit protection support
DC reverse connection support
Anti-surge protection support
Insulation resistance detection support
Leakage current protection support
General
Topology Transformerless
IP Rating IP65
Cooling Natural coolin
Operating Temperature Range -25℃-60℃
Relative Humidity Range 0-100%
Max. Operating Altitude 4000m
Noise <25dB
Dimensions(W*H*D) 285mm*336mm*125mm 335mm*426mm*125mm
Weight 8.8KG 12.8KG
HMI&COM
Display Blue-tooth & LED Indicator
Communication RS485(option), WIFI(optional), GPRS(optional)
Certification
Safety IEC62109-1, IEC62109-2, NB/T32004
EMC EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12
Grid Code NB/T32004, VDE-AR-N 4105, IEC 61727, AS4777

grid tie inverter.jpg

PRODUCT DETAIL

3kw grid tie inverter.jpg

2kw grid tie inverter.JPG

PRODUCT ADVANTAGE

3 phase grid tie inverter.jpg

APPLICATION

grid inverter.jpg

PRODUCTION LINE

on grid tie inverter.jpg

CERTIFICATE

on grid inverter.jpg

This product support custom development with fully your own logo

Main Export Markets


 

  • Eastern Europe

  • North America

  • Mid East/Africa

  • Central/South America

  • Asia

  • Western Europe

  • Australasia


     

FAQ

   1. Q: Can the motor(3ph. 200 volts) adjust the output voltage?

       A: Our VFD output voltage is 220V,so it can work with your 3ph. 200 volts.


   2. Q: How do I wire start stop button to VFD? I see x1-x5 but am clueless how to do it.

       A: When you complete a circuit between x1 - x5 and "common", whatever is programmed for x1 - x5 will be executed (ie. start, stop etc..) You will also need to set the unit for terminal control (I don't know the command number off hand). By setting the unit to terminal control, you will no longer be able to start and stop your machine directally from the VFD.


   3. Q: Does this thing need to be mounted in an electrical cabinet, or can I safely mount it to the side of a piece of     equipment?

       A: Yes,you can mount it in a box or just put it outside

Home  |  News  |  Products  |  Solutions  |  Service  |  About Us  |  Contact Us
Address:Second floor, building 3, Meijing Industrial Park, Yulu community, Yutang street, Guangming District, Shenzhen Tel:+86-755-83265566 Email:liuke@soyanpower.com
Copyright Shenzhen SoyanPower new energy Co., Ltd.
copyright © 2010-2015 http://www.soyanpower.com all rights reserved
  粤ICP备15051188